1) DrawConf/drawConfig.f
   Used to convert a 'config' to make stuff for display by
   Geomview or Gnuplot.
   The user may invoke the
      drawconfig
   command for a given "config_path" like
     "drawconfig config_path".
   This will prepare for the display.  Actual display is by the
     dispconfigbygeomv or dispconfigbygnupl command.
  ** special for honeycomb drawing.
     To draw all of the honeycomb structure sometimes results
     in error: too many vertexes in a component, and/or time consuming
     job. So, in defalut, the central part of the honeycomb drawing is
     simplified. The region for such central part can be controled
     by Util/DrawConf/Data/honeycomb.dat.
     
     
2) testCnf1.f
   Used to expand a given config.  It is used by the command
   expand "config_path" > output_file
   
3) testCnf2.f
   This is used to show Emin for each config component.
   (AutoEmin case).
   You have to come here to use this;
   you need config file and epicsfile.
   It's better to make links like
   (after  rm existing links)    
     ln -s  config_in_target_place  config
     ln -s  CnfgDir_in_target_placd  CnfgDir
     (say, if "config" needs CnfgDir in target_palce)
     ln -s  epicsfile_in_target_place  epicsfile

  Then,
  a) If config uses #news specifications, do
       usenewvol config
  b) make -f testCnf2.mk to  make "a.out"       
  c) Then enter next 3 lines
     ./a.out > outputfile     
     config
     epicsfile
4) testCnf3.f
   This is used to show quenching info.  for scintillators.
   You have to come here to use this;
   you need config file and epicsfile.
   The same procedure for link, compilation and execution
   as in 3), except for
  make -f testCnf3.mk in stead of    make -f testCnf2.mk.
  The output will have lines like below:
    2309 6 box SCIN 1 2 0 0 / -19.2715 -22.5 0.7005 3.2 45 1
    # quench info: T    8.00       0.360
    


[ev] is the optional event number. If omitted, 1 is assumed 
 xxxx can be
  all      for showing all tracks with no hidden mode
  allh     for  //                     hidden mode
  only+-   for  //    only charged particles with no hidden mode
  only+-h  for  //    only charged particles with  hidden mode
  only0    for  //    only neutral particles with no hidden mode
  only0h   for  //    only neutral particles with  hidden mode
  sort     for  //  only charged particles with different colors
                    for different  particle codes.   No hidden mode
  sort+-   for  //  only charged particles with differenct colors
                    for different particle codes and charges.
                   (no hidden mode)

5) To show 20 events sequentially, use
 
	a = -1 
	call "slide"

  if a =-1, after display of 1 event, system wait your "return"
     a = n (>0) //                        system wait  n sec.


  